Temperature & Humidity

  • ATEX Temperature Humidity Sensor
ATEX Temperature Humidity Sensor

ATEX Temperature Humidity Sensor

  • ATEX CE certificate
  • 4-20mA or RS-485
  • SIL2 SIL3 grade
  • Product description: GE-373-Ex ATEX Temperature Humidity Sensor could isolate the flammable point from external gas and dust, achieve the Ex grade to Ex db IIC T6 Gb (-20℃≤Ta+80℃), Ex tb IIIC T85℃ Db (-20℃≤Ta+80℃).
  • ISO9001 & ISO14001 & IS045001
GE-373-Ex Explosion Proof Temperature Humidity Sensor adopts a stabilized Ex-proof shell to isolate the flammable point from external gas and dust, achieve the Ex grade to Ex db IIC T6 Gb (-20℃≤Ta+80℃), Ex tb IIIC T85℃ Db (-20℃≤Ta+80℃). It has domestic and international ATEX explosion-proof certificates. There are a variety of range options, and the signal output can be 4-20mA or RS-485. 

Type:
GE-373-EX  wall mount type for room or outside area
GE-373-EX  insert type for duct or pipe air flow

The objection of the declaration is in conformity with the relevant EU harmonization legislation: ATEX directive 2014/34/EU, Machinery directive 2006/42/EC. The ATEX grade is Ex db IIC T6 Gb (-20℃≤Ta+80℃), Ex tb IIIC T85℃ Db (-20℃≤Ta+80℃)  IP65;  or Ex II 3GD Ex dc IIC T6 Gc (-20℃≤Ta≤+80℃) and Ex tc IIIC T85℃ Dc (-20℃≤Ta≤+80℃)  IP65 for gas and dust explosion prevention。



Specification:
Relative Humidity:
* Sensor: Capacitance polymer
* Range: 0~100%RH
* Output: 4~20mA / 0~10VDC / RS485
* Accuracy: 2%, 3% and 4.5%RH(25°C, 20~80%RH)
* Hysteresis: ﹤±1%RH
* Response time: ﹤10s ( 25 C, in slowly flow air)
* Drift: ﹤±0.5%RH/year

Temperature:
Sensor: Solid state band gap, RTD or thermistors
Range: 0~50°C  0~100°C or -40~120°C or other
Output: 4~20mA/0~10V/RS485, RTD or thermistors
Accuracy: ﹤±0.2 C @ 25 C

Electronic:
Power: Voltage 15~35VAC/DC, current 7.5-36VDC
Output Load: <500Ω (current), >2KΩ (voltage)
Display: Large LCD screen digital display, optional
Display Accuracy: 0.1°C, 0.1%RH
Display Resolution: 0.1°C, 0.1%RH
PREVIOUS:GE-114 Flow IndicatorNo next