Flow Meter

  • Open Channel Flowmeter GE-1208
  • Open Channel Flowmeter GE-1208
Open Channel Flowmeter GE-1208Open Channel Flowmeter GE-1208

Open Channel Flowmeter GE-1208

  • Triangle weir or Rectangular weir
  • Parshall flume flow meter
  • CE Certificate
  • ATEX Explosion Proof is available
  • Product description: GE-1208 Open Channel Ultrasonic Flowmeter could work with Parshall flume, Triangle Rectangular weir, 4-20mA RS-485 output, Explosion proof
  • ISO9001 & ISO14001 & IS045001
GE-1208 Open Channel Ultrasonic Flow Measurement Meter Instrument is widely applied by the various sewage discharging enterprises for online flow monitoring on the sewage discharges. The Open Channel Ultrasonic Flow Measurement transducer will not contact with the liquid, so it will be Dirt Resistant and Corrosion Proof. This Open Channel Ultrasonic Flow Measurement meter is stability and low maintenance, widely applied by the various sewage discharging enterprises for online monitoring on the sewage discharges, and is the best choice by the bureaus of environment protection at all levels and the sewage discharging enterprises to meter and manage the sewage discharges.

Model:
GE-1208S  Separated Body Open Channel Ultrasonic Flowmeter;
GE-1208T  Explosion-Proof Open Channel Ultrasonic Flowmeter

Uninterruptible Power Supply Type, UPS battery flowmeter is available.



Rectangular weir flow meter
Character :
* Data Storage Function
* All Kinds of output signal
* Parshall flume, Triangle weir (500mm) ,
Rectangular weir (250mm, or 500mm or 750mm, or 1000mm)
* High Accuracy with stability performance
* Customized Service is available



Specifications:
1. Transducer:1. Transducer:
* Level Distance Range: 0.3m ~ 10.0m
* Measure Accuracy: 0.2% FS
* Level Distance resolution: 1mm
* Acquisition frequency : 1-5HZ
* Frequency: 20kHZ ~ 50kHZ
* Emission beam : 9- 15°
* Output: 4~20mA, Alarm for high/low limit

(current loop on 3 wires cable, distance maximum 300M)


2. Transmitter
* Flow range: 0 ~ 10m3/s (0 ~ 10, 000L/s)
* Cumulative flow: 0~ 99999999 cubic meter
* Blind area: 0.25m~0.5m
* Flow precision: 1%~4%(subject to the type of weir plate)
* Pressure: Less than 4 atmosphere pressure
* Display: LCD displays the instantaneous flow and cumulative flow
* Analog output: 4~20mA
particular output current (0-20ma) is available for option
* Fault output in screen display
* Resolution : 0. 1% of the measured range or 2mm
* Max Load: not less than 600Ω
* Input/output insulation: max 550V
* Digital output:RS485,Modbus agreement or customized agreement
* Power voltage: DC24V/AC220V,built-in lightning proof device
* Ambient temperature: -5C ~ 70C
* Protection grade: IP65